Repeated Accuracy: △E<0.03. Color Difference Formula: △E ab. Table Difference: △E<0.2. Working Temperature Range: 0℃-40℃( 32℉-104℉ ). Storage Temperature Range: -20℃-50℃( -4℉-122℉ ). Humidity Range: Relative humidity less than 85%,without condensation.
Tablet Friability Tester Friability Testers with Rotation Speed Range 25rpm
Rotation speed range: 25rpm. The friability tester is used to check the friability and other physical strengths of uncoated tablets, such as crushing strength. Rotation speed accuracy: ±1 rev/min. Depth of turntable cylinder: 39mm.
Tablet Friability Test Apparatus with Rotation Count (10~900)r Cylinder Number 2
Applicable standards Industry standard (Tablet friability tester) Features Rotation speed range: 25 rpm. Rotation speed accuracy: ±1 rev/min. The drum is made of high quality hyaline acryl. Automation: auto-test, auto-diagnose, auto-alarm.
Silver Ion Meter Ag Ion Meter Tester with 2 to 5 Point Calibration USB Interface
Ion Concentration. Ag silver electrode. Automatic temperature compensation ensures accurate readings over the entire range. USB communication interface. BNC, 3.5mm jack socket. 170(L)×85(W)×30(H)mm. 1×10-7 to 1M, 0.01 to 107900ppm.
Cadmium Ion Meter Cd Ion Tester with Cadmium standard solutions USB Interface
Ion Concentration. Cd cadmium electrode. USB communication interface. BNC, 3.5mm jack socket. 170(L)×85(W)×30(H)mm. 10, 20 or 30 minutes after last key pressed. Custom LCD (80×60mm). 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000.
Tablet Friability Test Apparatus with Rotation Count (10~900)r Cylinder Number 2
Applicable standards Industry standard (Tablet friability tester) Features Rotation speed range: 25 rpm. Rotation speed accuracy: ±1 rev/min. The drum is made of high quality hyaline acryl. Automation: auto-test, auto-diagnose, auto-alarm.
Portable Lead Ion Meter Pb Ion Tester Water Samples Tester With USB Interface
Ion Concentration. Automatic temperature compensation ensures accurate readings over the entire range. USB communication interface. 10, 20 or 30 minutes after last key pressed. BNC, 3.5mm jack socket.
Cadmium Electrode Cadmium Ion Electrode for Cadmium Ion Meter with Solutions
Cadmium ion selective electrode, range: 0.1 to 11200 ppm. Cd Cadmium Electrode Combination cadmium ion selective electrode. Built in dry reference electrode. Electrode Includes. Cadmium standard solution 1000 ppm (30 mL).
Portable Turbidity Meter with 0-1000NTUCalibration Solution For Sewage Treatment
Zero drift ± 0.8%F.S. Repeatability: ≤ 0.8%. Indication error: ± 8% (± 2.5%F.S).
Cd Electrode Cd Ion Electrode for Cd (Cadmium) Ion Meter with Standard Solutions
Cadmium ion selective electrode, range: 0.1 to 11200 ppm. Cd Cadmium Electrode Combination cadmium ion selective electrode. Built in dry reference electrode. Electrode Includes. Cadmium standard solution 1000 ppm (30 mL).